Send Message
Home > products > Chiller Lab Equipment >
Chiller Lab Equipment 50L Glycol Circulating cooling Chiller For Evaporator

Chiller Lab Equipment 50L Glycol Circulating cooling Chiller For Evaporator

-80℃ Lab Chiller Unit

50L Lab Chiller Unit

50L chiller lab equipment

Place of Origin:

China

Brand Name:

Lanphan

Certification:

CE ISO

Model Number:

DLSB 50L-80℃

Contact Us
Request A Quote
Product Details
Product Name:
Chiller
Product Model DLSB 50L-80℃:
DLSB 50L-80℃
Volume:
10L
No-load Minimum Temperature:
-80℃
Circulating Pump Power:
280W
Circulating Pump Flow:
30L/min
Circulating Pump Head:
12 M
Outer Loop Interface:
16 M
Net Weight:
315 Kg
Gross Weight:
385kg
Cooling Capacity:
368~19110W
Total Power:
8230W
Electric Current:
37.5 A
Warranty:
1 Year
Highlight:

-80℃ Lab Chiller Unit

,

50L Lab Chiller Unit

,

50L chiller lab equipment

Payment & Shipping Terms
Minimum Order Quantity
1
Price
$ 7850
Packaging Details
Carton, wooden cases or customizable package
Delivery Time
5-8 work days
Payment Terms
L/C, D/A, Western Union, T/T
Supply Ability
1000 Sets per Month
Product Description

Chiller Lab Equipment 50L Glycol Circulating Cooling Chiller For Evaporator

 

Chiller Application

 

The purpose of the chiller: DLSB- series chiller is a low temperature liquid circulating equipment using mechanical refrigeration, which can provide constant current and constant pressure circulation cooling liquid to meet the operating temperature of the instrument of electron microscope, electron probe and ultra high vacuum splash, radiography, X-ray machines, lasers, reactors, accelerators, etc . For instruments that work in a lack of water, poor water quality or high temperatures, they can keep working properly. It can provide cryogenic liquids, which is combined with rotary evaporator, vacuum drying oven, circulating water multi-purpose vacuum pump, magnetic stirrer and other instruments for chemical reaction operation and drug storage under multi-functional low temperature. The equipment is especially suitable for various chemical, biological and physical laboratories that need to keep working under low temperature conditions. It is an indispensable equipment for laboratories, which can be used in the medical and health, food industry, metallurgical industry, and colleges and universities.

 

Chiller Description

 

DLSB 50L-80℃ Laboratory chiller adopts microcomputer intelligent control system. Low temperature cooling liquid circulating pump with low temperature cooling water (liquid) flow or low temperature constant temperature water (liquid) flow, in order to meet the needs of the cooling water and low temperature liquid cooling or constant temperature equipment, such as the rotary evaporation apparatus, fermentation tank, electron microscope, low temperature chemical reaction kettle, electron spectrometer, mass spectrometer, densimeter, freeze-drying machine, vacuum coating machine, reaction kettle, etc.

 

Chiller Principle

 

The low temperature cooling circulation pump of this equipment adopts microcomputer intelligent control system. Low temperature cooling liquid circulating pump with low temperature cooling water (liquid) flow or low temperature constant temperature water (liquid) flow, in order to meet the needs of the cooling water and low temperature liquid cooling or constant temperature equipment, such as the rotary evaporation apparatus, fermentation tank, electron microscope, low temperature chemical reaction kettle, electron spectrometer, mass spectrometer, densimeter, freeze-drying machine, vacuum coating machine, reaction kettle, etc.

 

Troubleshooting

 

Make sure the refrigerant used is correct. In most cases, more than 97% ethanol solution is required


Refrigerant filling should be kept on the same level with the coil in the liquid storage tank, but not too much or too little
Check whether the compressor has fluorine: ≥30L


It should be noted that when the refrigerant temperature is lowered to the set value by the refrigeration pump, it is forbidden to add any refrigerant to the cold storage.


When the pump runs slowly or the refrigeration is poor, the condenser needs to be cleaned

 

 

 

Chiller Parameter

 

 

Product Name Chiller
Product Model DLSB 50L-80℃
Non-Loaded Minimum Temperature -80℃
Temperature Fluctuation ±2℃
Refrigerant R404
Volume 50L
Circulating Pump Power 100W
Lift (Optional) 12 M
Net Weight 315kg
Gross Weight 385 kg
Total Power 8230W
Condation New

Chiller Lab Equipment 50L Glycol Circulating cooling Chiller For Evaporator 0Chiller Lab Equipment 50L Glycol Circulating cooling Chiller For Evaporator 1Chiller Lab Equipment 50L Glycol Circulating cooling Chiller For Evaporator 2

 

Chiller Lab Equipment 50L Glycol Circulating cooling Chiller For Evaporator 3Chiller Lab Equipment 50L Glycol Circulating cooling Chiller For Evaporator 4Chiller Lab Equipment 50L Glycol Circulating cooling Chiller For Evaporator 5

 

 

 

 

Send your inquiry directly to us

Privacy Policy China Good Quality Vacuum Freeze Dryer Supplier. Copyright © 2020-2025 Henan Lanphan Industry Co.,Ltd . All Rights Reserved.