Send Message
Home > products > Chiller Lab Equipment >
Circulation Coolant 100L 12630w Lab Chiller Unit

Circulation Coolant 100L 12630w Lab Chiller Unit

12630w Lab Chiller Unit

100L Lab Chiller Unit

Circulation Coolant Lab Chiller Unit

Place of Origin:

Henan, China

Brand Name:

Lanphan

Certification:

ce, ROHS

Contact Us
Request A Quote
Product Details
Applicable Industries:
Machinery Repair Shops, Manufacturing Plant, Energy & Mining
After Warranty Service:
Video Technical Support, Online Support
Local Service Location:
United States
Showroom Location:
United States
Condition:
New
Type:
Water-cooled
Voltage:
220w
Dimension(L*W*H):
120*110*135 Cm
Weight:
385 Kg
Warranty:
1 YEAR
After-sales Service Provided:
Video Technical Support, Online Support
Power(W):
12630w
Working Temperature Range:
-80℃
Key Selling Points:
High-accuracy
Lowest No-load Temperature:
-30℃
Best Temperature Range:
≤25℃
Environmental Relative Humidity:
≤70%
Temperature Display Mode:
Liquid Crystal
Temperature Stability:
±2℃
Sensor Index:
Pt100
Instrument Adjusting Range:
±150℃
Safety Protection:
Delay,leakage,over Current,overheat
Refrigerant:
R404A
Port:
Shanghai, Tianjin, Qingdao
Highlight:

12630w Lab Chiller Unit

,

100L Lab Chiller Unit

,

Circulation Coolant Lab Chiller Unit

Payment & Shipping Terms
Minimum Order Quantity
1 - 2 Units
Price
$11,920.00
Packaging Details
Packing of Coolant Pump: carton or wooden case package, customized package is available.
Supply Ability
1000 Set/Sets per Month
Product Description

Laboratory Low Temp Cooling Liquid 100L Circulation Coolant Pump

The capacity of our refrigeration pump can be 5L-500L
Temperature ranges from room temperature to -120 degrees

Product Description

Circulation Coolant 100L 12630w Lab Chiller Unit 0

DLSB-100 series low temperature coolant circulation pump, also known as low temperature cooling water circulation pump, cryogenic pump, low temperature circulation pump, low temperature cooling circulation pump,etc. It is a low-temperature equipment that uses a compressor for mechanical refrigeration. The tank has a volume of 50L. The lowest temperature at no load can meet -23°C~-120°C, and the temperature can be adjusted from -10°C to-120°C. On the basis of refrigeration, a circulating water pump is added to enable the cooled liquid to pass through the pipeline for external circulation and internal circulation, and can provide low temperature for external equipment such as double-layer glass reactor, organic synthesis device, rotary evaporator, etc. The liquid can also be combined with a rotary evaporator, a vacuum freeze drying oven, a circulating water vacuum pump, a magnetic stirrer and the like to perform chemical reaction operations and drug storage at a multi-functional low temperature.LSB-100 series low temperature coolant circulation pump constant current, constant pressure, circulating fluid can provide cooling water to meet the requirements of temperature and water purity, for high purity metal, rare substance purification, environmental experiment and magnetron sputtering, vacuum coating Such large equipment, low temperature coolant circulation pump can also meet the cooling needs of electronic instruments, electronic
probes, ultra-high vacuum sputtering instruments, X-ray machines, lasers, accelerating Qi Deng and other valuable equipment. The cryogenic coolant circulation pump is especially suitable for chemical, biological and physical laboratories that need to maintain low temperature and normal temperature conditions. It is a medical and health,chemical industry, food industry, metallurgical industry, colleges and universities, scientific research, genetic engineering, polymer engineering. The necessary equipment in the laboratory (can be customized according to user needs, large-capacity low-temperature coolant circulation pump).

Circulation Coolant 100L 12630w Lab Chiller Unit 1
Specification model DLSB-100/20  DLSB-100/30  DLSB-100/40  DLSB-100/60  DLSB-100/80  DLSB-100/120
Liquid storage volume 100L  100L  100L  100L  100L  100L
No-load minimum temperature -23 -32 -40 -63 -83 -120
Cooling capacity 11245-2821  11380-3012  11520-3160  12300-7627  12630-2160  13760-1350
Temperature range -20℃  -30℃  -40℃  -60℃  -80℃  -120℃
Max vacuum degree(pa) ±2  ±2  ±2  ±2  ±2  ±2
power supply(V/HZ) 380/50Hz  380/50Hz  380/50Hz  380/50Hz  380/50Hz  380/50Hz
temperature(℃ ) 25 25 25 25 25 25
Dimensions(mm)

1100*900

*1100 

1100*900

*1100 

1100*900

*1100 

1200*1100

*1350

1200*1100

*1350

1460*1200

*1350

Flow 70L/min  70L/min  70L/min  70L/min  70L/min  70L/min
Head (M) 6-8m  6-8m  6-8m  6-8m  6-8m  6-8m

 

PRODUCT PARAMETER:

 

1. Imported air-cooled fully enclosed compressor unit with advanced performance and reliable quality;

2. Refrigerant unit special relays, protectors, capacitors, refrigeration components, imported high quality components;
3. Digital display thermostat display, microcomputer temperature control, simple and eye-catching operation;
4. Large cooling capacity and fast cooling speed greatly improve work efficiency;
5. It can effectively protect the normal use of all kinds of precision equipment and instruments under the conditions of lack of water source,water quality, water pressure, poor water temperature and high temperature working conditions;
6. The circulation system is made of stainless steel and has the functions of anti-corrosion, anti-rust and anti-cold liquid pollution;
7. At low temperature, the coolant can be delivered to the place where it is used, and the original circulating pump of international famous factory is installed inside;
8. The microcomputer intelligent control refrigeration system is automatically turned on, and the refrigeration system has multiple protection devices such as delay, overheat and over current.

Turn on and off:
The right turn to turn on the machine: Add the appropriate refrigerating medium—connect the power with the special power supply—turn off the circulation switch—press the power button—open the circulation switch—open the switch—open the cooling equipment
The right turn to turn off the machine.Turn off the cooling equipment—turn off the switch—turn off the circulation switch(stirring switch)—turn off the outlet valve(or discharge the cooling medium)—turn off the power supply —disconnect circuit breaker—disconnect the power line from the power supply—clean the equipment.
Corollary Equipment

Circulation Coolant 100L 12630w Lab Chiller Unit 2

Related Products

Circulation Coolant 100L 12630w Lab Chiller Unit 3Circulation Coolant 100L 12630w Lab Chiller Unit 4

The capacity of our refrigeration pump can be 5L-500L
Temperature ranges  from room temperature to -120 degrees

Company Information
Circulation Coolant 100L 12630w Lab Chiller Unit 5

Circulation Coolant 100L 12630w Lab Chiller Unit 6Circulation Coolant 100L 12630w Lab Chiller Unit 7

Circulation Coolant 100L 12630w Lab Chiller Unit 8
Circulation Coolant 100L 12630w Lab Chiller Unit 9
Circulation Coolant 100L 12630w Lab Chiller Unit 10

Send your inquiry directly to us

Privacy Policy China Good Quality Vacuum Freeze Dryer Supplier. Copyright © 2020-2025 Henan Lanphan Industry Co.,Ltd . All Rights Reserved.